American Standard SELECTRONIC 605X.205 Manual de instrucciones de instalación - Página 3

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Cocina & Accesorios de baño American Standard SELECTRONIC 605X.205. American Standard SELECTRONIC 605X.205 11 páginas. Hard-wired ac powered innsbrook lavatory proximity faucet

American Standard SELECTRONIC 605X.205 Manual de instrucciones de instalación
Fig. 1
FINISHED
WALL
35mm
(1-3/8)
DIA.
3 HOLES
57mm
(2-1/4)
81mm
(3-3/16)
3/8" COMP.
TOOLS REQUIRED; Fig. 2
1 Slip Joint Pliers
2 Adjustable Wrench
3 Plumbers' Putty or Caulking
4 Phillips Screwdriver
5 Flat Blade Screwdriver
6 Electric Drill & 1/4" Drill Bit
7 Tape Measure
INSTALLATION
INSTALL SPOUT ASSEMBLY;
1
Fig. 1
CAUTION
Turn off hot and cold water supplies before beginning
1. Make sure PUTTY PLATE (1) is installed on
FAUCET BODY (2). Fig. 1a.
2. Connect the two 27 " EXTENSION CABLES (3) to the
Faucet Sensor Cables.
3. Insert 27" EXTENSION CABLES (3), FLEX HOSE
(4) and STUDS (5) through holes of mounting surface.
Fig. 1a.
4. From underside of mounting surface, install SPIN
NUTS (6) onto MOUNTING STUDS (5). Fig. 1b.
5. Align FAUCET (2) and hand tighten SPIN NUTS (6)
to secure faucet to mounting surface. Fig. 1b.
175mm
(6-7/8)
162mm
(6-3/8)
124mm
(4-7/8)
108mm
MOUNTING
(4-1/4)
SURFACE
38mm
(1-1/2)
MAX.
102mm
125mm
(4)
(4-7/8)
114mm
(4-1/2)
500mm
(20")
Roughing-in Dimensions
155mm
(6-1/8)
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal resistant
solid brass construction single post mounting. Operates on
DC (battery/power pack) or AC permanent power
(plug-in/hardwire). In-line strainer for solenoid is integral.
Single inlet 3/8 compression, built-in check valves, and
flexible stainless steel 16-1/4" reach inlet hose for spout
connection.
Note: All plumbing and electrical wiring must be
installed in accordance with applicable codes,
regulations and standards.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
381mm
(15)
RECOMENDED ELECTRICAL BOX OR
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP ELECTRICAL BOX
HARD-WIRED AND MULTI AC 10' MAX. CABLE LENGTH
Fig. 2
3
Fig. 1a
SENSOR
CABLES
3
Fig. 1b
2
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
1
7
6
4
10'
5
5
2
4
3
5
6
6
5
M 9 6 5 6 5 2 ( 11 / 14 )
2
1