INSTALLER'S GUIDE
NOTE: For model base size,
see table on page 7.
After installation has been completed, it is recommended that the entire system be checked against the following list:
1. Refrigerant Line, Leak checked ................................. [ ]
2. Suction Lines and Fittings properly insulated ......... [ ]
3. Have all Refrigerant Lines been secured and
isolated properly? ........................................................ [ ]
4. Have passages through masonry been sealed?
If mortar is used, prevent mortar from coming
into direct contact with copper tubing ....................... [ ]
5. Verify tightness of all electrical connects .................. [ ]
6. Observe outdoor fan during on cycle for clearance
and smooth operation ................................................. [ ]
Technical Literature - Printed in U.S.A.
American Standard Heating & Air Conditioning
Troup Highway
Tyler, TX 75707
PAGE 8
MoUNTING HoLE LocATIoN
NoTE: ALL DIMENSIoNS ARE IN MM (INcHES).
cHEckoUT PRocEDURE
7.
Indoor coil drain line drains freely. Pour water
into drain pan .............................................................. [ ]
8.
Supply registers and return grilles open and
unobstructed ............................................................... [ ]
9. Return air filter installed ........................................... [ ]
10. Thermostat thermometer is accurate. Check
against a reliable thermometer. Adjust per
instructions with thermostat ..................................... [ ]
11. Is correct speed tap being used?
(Indoor blower motor) ................................................. [ ]
12. Operate complete system in each mode to
insure safe operation. ................................................. [ ]
From Dwg. D152637 Rev. 2
Pub. No. 11-BC08D1-7