American Time SiteSynq IQ Manual de instalación y funcionamiento - Página 15
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Reloj American Time SiteSynq IQ. American Time SiteSynq IQ 19 páginas. Wireless digital clocks
Wireless Digital Clocks Owner's Manual
Wireless Digital Clocks Owner's Manual
Important Considerations
The ATSTCS must be in the RUN mode for Code Blue to override.
The 12vac/vdc to 30vac/vdc signal that starts the Code Blue timer originates from equipment external to the Digital
Clock/Timer. The external equipment usually employs a switch device (i.e., a relay contact) to apply this signal. That
switching device is often referred to as the Code Blue contact.
The Code Blue contact does not have to open before resetting the Digital Clock/Timer back to normal operation, but
must be opened before another Code Blue can occur. The transition from no voltage to applied voltage (across the
K2+ and K2- terminals) initiates a Code Blue.
If the Code Blue contact opens and closes again before the Digital Clock/Timer is reset back to normal operation, the
Code Blue timer will start over from 00:00:00.
If a power failure occurs during any Code Blue event, the Code Blue timer will start over from 00:00:00.
System Maintenance
The Digital Clock/Timer and ATSTCS Control Station have been manufactured for years of dependable, reliable
use. However, to assure the reliability of this product, it is recommended that the Digital Clock/Timer be tested at
least every six (6) months with the Control Station and Code Blue contact for operation in accordance with wiring
configurations used.
© American Time
© American Time
Optional Code Blue Function
15