Dontek Aquasun 3 Manual de instrucciones - Página 3
Navegue en línea o descargue pdf Manual de instrucciones para Controlador Dontek Aquasun 3. Dontek Aquasun 3 8 páginas.
MODE OF OPERATION
Pressing the SELECT button once will display
the current mode of operation, pressing it
again or holding it will select the next
available mode of operation.
The available modes are SUMMER, MANUAL,
TROPICAL or WINTER.
Summer mode
Summer mode
Summer mode
Summer mode
is the normal operating mode
for heating the pool.
Winter mode
Winter mode
Winter mode
Winter mode
of operation is for off-season
maintenance or if pool heating is not required
(AWAY MODE)
. This is a better option than
turning off the controller as it will flush
treated pool water through the solar system
as well as prolong pump bearing and
mechanical seal life. The pump will run for 3
minutes each day from when the winter mode
was selected or at 10am if the time-clock
mode was selected.
Tropical
Tropical mode
mode
Tropical
Tropical
mode
mode
is for situations where the
pool
water
overheats
temperature limit due to direct heating from
the sun. The unit will attempt to sample the
pool water when solar gain is available and if
after 3 minutes the pool is above the desired
temperature limit then the controller will wait
until the roof is 4°C cooler than the pool
temperature, the pump is then started to cool
the pool (this will most likely occur at night).
Manual mode e e e
Manual mod
Manual mod
Manual mod
is for testing the pump
installation on a cold or cloudy day. Once
manual mode is selected the pump will start
if it has been off, or stop if it has been on
(running). After 30 minutes manual mode will
time-out and return to Summer Mode with a
default temperature limit of 30°C
Settings mode
Settings mode
Settings mode
Settings mode
is for setting the unit into
time-clock operation.
When you select this option you will be asked
if you wish to use the clock feature (CLK?
ON/OFF).
If you select OFF then the controller will not
work as a time-clock model and will prevent
Aquasun 3 Instruction_rAD.docx
beyond
the
set
starting the pump to sample at night based
on a sequence of events.
If you select ON you will be prompted to set
the time of day, the controller will work in
time-clock mode and the solar pump is
prevented from starting outside of the set
hours (unless tropical mode is selected). Set
the time of day in 24 hour format, note there
is an AM/PM indication to avoid incorrect
settings. Seconds are automatically set to
zero.
Once the time is set select the START hour
from 6am till 12 noon, default is 9am which
means the solar pump cannot start before
9am.
Now select the END hour from 15:00 (3pm)
until 21:00 (9pm), default is 19:00 (7pm)
which means the solar pump will stop at 7pm.
INSTALLER
SETTINGS
DIFFERENTIAL
FEATURES:
Special note: Adjusting these values to any
setting other than the defaults may adversely
affect the performance of this controller. To
select these features, hold the DOWN button
then press SELECT. When you select this
option you will be prompted to set the solar
gain start temperature (RUN° x) this setting
allows the pump to start if the roof
temperature exceeds the last valid pool
temperature or pipe temperature by this
value, adjust with the UP/DOWN button, press
SELECT to accept. Next you will be prompted
to set the differential hysteresis (END° x)
which turns the pump off when roof
temperature
is
temperature plus this value, adjust with the
UP/DOWN button, press SELECT to accept.
Default values are 8° for RUN and 4° for END,
these are the optimal values for maximum
efficiency, some coastal locations may
benefit from a reduced run value of 6°C for
RUN and 4°C for END.
The next item is anti-freeze, you will be
prompted by FRZ? ON/OFF, adjust with the
-
ADJUSTABLE
&
ANTI-FREEZE/BOIL
less
than
the
pool
3