AmeriFlow Water Systems Inc. ET6500 Manual del usuario - Página 14

Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua AmeriFlow Water Systems Inc. ET6500. AmeriFlow Water Systems Inc. ET6500 17 páginas. Reverse osmosis systems

AmeriFlow Water Systems Inc. ET6500 Manual del usuario

PERFORMANCE DATA SHEET

REVERSE OSMOSIS SYSTEM MODEL NUMBERS 1-1310-10, 1-1320-10
REPLACEMENT TREATMENT COMPONENTS SEE STEP 9, PAGE 8
GENERAL INSTALLATION — OPERATION — MAINTENANCE REQUIREMENTS
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before of after the system.
• This reverse osmosis system contains a replaceable treatment component critical for effective
reduction of total dissolved solids. The product water shall be tested periodically to verify that
the system is performing properly.
• While testing was performed under standard laboratory conditions, actual performance may
vary.See Owner's manual for Manufacturer's limited warranty.
• This system has been tested and shown to operate at its calculated recovery rating and ef-
ficiency rating under standard test conditions.
• Chlorine in the influent water may affect the R/O membrane polymers.
• See Owner's manual for complete installation / operation and maintenance requirements, as
well as user responsibility and parts and service availability.
Pentair Membrane 655006-00 RODTP Contaminant Reduction Information for PDS
Daily Production Capacity
Rejection Rate
Storage Capacity
Recovery Rating*
Efficiency Rating*
System Weight
System Dimension
Storage Tank Dimension
Min./max. pressure
Min./max. temperature
*Recovery Rating
is available to the user as reverse osmosis treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
to the system that is available to the user as RO treated water under operation conditions that approximate
typical daily usage.
13
07\15 RO Manual
7.7
93.3%
2.6 gallons
22.4%
11.7%
27 lbs.
16" x 15.5" x 7"
15.5" x 11"
40 – 85 PSI
40° - 110° F
means the percentage of the influent water to the membrane portion of the system that
*PERFORMANCE INDICATOR.
be tested regularly to verify that the system is perform-
ing properly. Testing can be accomplished by contacting
the service company that installed your RO system or an
authorized dealer. If a service company is not available in
your area a water sample may be sent to AmeriFlow™ for a
free TDS test of your RO water. Additionally a water quality
monitor is available for purchase from the manufacturer
that will allow the product water to be tested at home.
Test parameters: 25°+ 1°C, 45 PSI, and pH of 7.3
*Efficiency Rating
means the percentage of the influent water
The product water shall