Astonica 40200112 Manual de instrucciones - Página 2
Navegue en línea o descargue pdf Manual de instrucciones para Fuente al aire libre Astonica 40200112. Astonica 40200112 3 páginas. Two tier fountain
3. (SEE FIGURE 3) Insert the PVC tube from top
basin (D) through center pedestal (C) and onto
the spout of the electric pump (E).
4. Then align the tabs of top basin (D) with
notches of center pedestal (C) and secure
by twisting.
5. (SEE FIGURE 4) Fill the large basin (B) with
water; if possible use distilled water to
fill the basin.
6. Plug power cord of pump (E) into properly
grounded 120V AC outlet. Allow a few minutes
for the water to begin flowing.
Adjust Speed of Water Flow
1. Unplug pump (E) from AC power outlet.
2. Move adjustment switch on pump (E)
toward "+" positive to increase water
flow, or "-" to decrease water flow.
Maintenance
1. Check water level periodically, add
water if necessary.
NOTE: Pump may build up calcium after a
long period of time and stop running when
tap water is used. Any calcium remover can
be used to clean pump.
Figure 3
D
C
B
A
Figure 4
Grounded
Outlets
B
4
ELECTRICAL SAFETY INSTRUCTIONS
WARNING!
instructions listed below, may result in electrical shock, fire and/or serious personal injury.
Grounding Instructions
This fountain must be plugged into a 3-wire, 3-prong outlet that is properly working and has
been installed and grounded in accordance with all local, state or federal codes and ordinances.
DANGER:
ELECTRICAL SHOCK. Check with a qualified electrician or serviceman if the grounding instructions
are not completely understood, or if doubt as to weather the product is properly grounded. Do not
modify the plug provided; if it will not fit the outlet, have a proper outlet installed by a qualified
E
electrician. Do not use any type of adapter with this product.
Outdoor Use Extension Cords.
1. When product is used outdoors, use only extension cords marked for outdoor use.
2. Use only UL listed extension cords. Never use damaged or altered extension cords.
3. Follow extension cord manufacturer safety instruction.
Extension Cords
1. Make sure your extension cord is in good condition.
2. When using extension cords, be sure to use one heavy enough to carry the current your product
requires. An undersized cord will cause a drop in line voltage resulting in power loss and
overheating. Reference Table 1 at the bottom of the page for the correct size to use depending
on cord length and nameplate Ampere rating. If in doubt, use the next heavier gage. The smaller
the gage number, the heavier the cord.
Table 1. Minimum Recommended Extension Cord Gauge (AWG) Chart
E
ELECTRICAL SHOCK. Read and understand all instructions. Failure to follow all
SAVE THESE INSTRUCTIONS.
IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF
AMP Load
Volts Extension Cord Length
120V
25'
50'
100'
AWG
1-5
18
16
16
6-10
18
16
14
10-12
14
14
14
12-16
14
12
Not recommended
1
150'
14
12
12