Air Delights E-60 Instrucciones de instalación y funcionamiento - Página 3
Navegue en línea o descargue pdf Instrucciones de instalación y funcionamiento para Calentador de agua Air Delights E-60. Air Delights E-60 4 páginas. Chronomite instant-temp water heaters
OPERATION INSTRUCTIONS:
Turn the hot water faucet to activate the flow switch. The flow switch activates at one gallon per minute (GPM) and deactivates at .65
gallon per minute.
If you increase the flow rate the water will become cooler. Cold water can always be mixed when using a two handle faucet.
Once you decrease the flow rate to 0.65 GPM the unit will deactivate. The microprocessor will supply the correct amount of power
(amperage x voltage) to maintain the temperature at the pre-selected temperature with varying flow rates.
>Periodically inspect the supply lines, connections and heater for any moisture, corrosion or other potential preventable problems.
HOW THE INSTANT-TEMP WORKS
The steel case houses a series of ingeniously designed coils that instantly heats water as it flows through the vessel. A unique power
switch automatically applies electrical current to the coils when hot water is being requested. The electrical current is not applied
when the heater is not in use. The microprocessor maintains a constant output temperature at the pre-selected temperature.
FLOW CONTROLS SUPPLIED
You may want to install the supplied flow control in your design. The high quality Omni flow controls allow the water heating system
to operate more effectively. The supplied 2.0 GPM faucet flow control assures the flow rate will not exceed 2.0 GPM. However, less
water can always be used, and they will save water and energy. Consumers can mix the cold water as with a conventional system.
FLOW CONTROL MODELS
Standard Flow Models
A-212 (Male/Female)
FLOW CONTROL SPECIFICATIONS
Material:
Chrome plated, brass housing.
Threading:
MODEL A212 and L212 have Male (outside) threads for
faucets with 15/16" Female threads and 55/64" Male threads.
*Flow controls are adaptable to other thread configurations.
Please call factory if an adapter is needed.
Potentiometer (Optional Field Temperature Control)
The potentiometer allows the factory preset temperature of the heater to be
changed in the field. The potentiometer will adjust water temperature between 70
the heater supplied is capable of producing the temperature increase. See temperature chart for each model on page 4 of
installation sheet to determine the temperature range of the heater installed.
The Instant-Temp heater will default to original factory preset temperature if the potentiometer is disconnected.
If the potentiometer is not needed, remove the front cover of the housing and simply tuck the connector between the
microprocessor board and the bottom of the back housing, Replace the front of the housing to secure the internal parts.
When using the potentiometer please use the following installation and operation instructions:
1. Mount potentiometer to wall using bracket supplied as shown in figure 4.
2. Connect the quick connect of the potentiometer to the connection found on the lower right side of the heater.
3. To increase temperature:
a. Loosen nut
b. Using a screwdriver, turn screw in small increments clockwise (to the right)
c. Once temperature of the water is acquired, tighten the nut
4. To decrease water temperature:
a. Loosen nut
b. Using a screwdriver, turn screw in small increments counter clockwise (to the left)
c. Once temperature is acquired, tighten the nut
:
GPM
2.0
Low Flow Models
GPM
L-212 (Male/Female)
0.5
FIGURE 2
FLOW CONTROL INSTALLATION
(See Parts List #8)
°F providing the wattage of
°F and 120
3