CW PROCEDURE
Follow these instructions in numerical order. If the various meter
readings are different than indicated, check the connections from
the exciter to the amplifier and make sure they are correct.
Consult the manual for the exciter.
Be sure the transformer is correctly installed and wired for your
line voltage. See the "Transformer Installation" section on page 4
and 5 for wiring details.
1.
Set the AL-1500 front panel switches as follows:
POWER TO OFF
OPR-STBY TO STBY
SSB-CW TO CW
MULTIMETER TO HV
2. Plug the AC line cord into the proper voltage outlet.
3. Set the Power Switch to the ON position. The grid meter
should light and the blower should start. After three minutes,
the plate meter should light and the multimeter should read
3600 volts nominal and absolutely no more than 3700 volts
HV.
4. With the amplifier still on STANDBY. tune the exciter into a
normal 50 ohm load according to the manufacturer's
instructions. Turn the exciter drive fully down after tuning.
5. Place the amplifier mode switch in the CW position, the
bandswitch on the same band as the exciter, the PLATE
control in the dial range for the band selected and the load
control as indicated:
6. With exciter drive still at zero, place the MULTIMETER
switch in the Ip position. Observe the 1000 mA scale. The
meter should read zero (0). Place the STBYOPR switch in
the OPR position.
7. Key the exciter (no drive) and observe the plate current on the
1000 mA scale. It should be 75 mA. Place the CW-SSB
switch in the SSB position. Plate current should now read
250 mA. Return the CW-SSB switch to the CW position.
Note: The no drive currents will vary up to 25% due to
component and line voltage tolerences.
8. Apply only enough drive to indicate a grid current of 50 mA or
an Ip of no more than 500mA. Tune the PLATE control for
maximum output power or grid current. It is normal for the
plate current to dip at this point.
goes over 100 mA. reduce the drive at once. Unkey the
exciter.
NOTE: This amplifier has a circuit that protects
the tube from excessive grid current. If 175 mA of peak grid
current is reached, the "OPR" LED will no longer light and
the amplifier will go into a bypass condition. This overload
condition can be reset by momentarily putting the
STBY/OPR switch in the STBY position. Repeated tripping
of the grid overload circuit usually indicates that the loading
control is set too far counterclockwise for the amount of
drive being applied to the amplifier or that something in the
antenna system is changing impedance (arching) during
9. Place the MULTIMETER switch in the PO position and
observe the 2000 Peak RF Watts scale. Increase the drive
until 100 mA of grid current is indicated. Adjust the LOAD
and PLATE controls for maximum output. The grid current
may be lower now.
10. Advance the drive to 100 mA of grid current. Adjust the
LOAD and PLATE controls for maximum output power. The
output should be over 1000 watts now.
11. Apply full drive without exceeding 100 mA of grid current.
The final grid current should be around 50 mA and the plate
current below 1000 mA.
If the grid current