Astralpool KEFREN Manual de instalación - Página 10
Navegue en línea o descargue pdf Manual de instalación para Equipos de iluminación Astralpool KEFREN. Astralpool KEFREN 12 páginas. Inground and half-inground bin
También para Astralpool KEFREN: Manual de instrucciones (12 páginas), Manual de instrucciones (12 páginas)
4. STARTING UP
1. Only in KEOPS bin. Take out both bin's lids to begin the starting. Unbolt the
bolts which join the lid with the bin, before holding up it.
2. Open the filter and fill it with water until the middle of it. Protect the diffuser
from the interior of the filter so as to prevent the entrance of sand in it.
3. Fill the filter with silex sand, with a grading 0.4-0.8. The quantity has to be
suitable with the quantity indicated in the featuring label or it has to be 2/3 parts
of the total high of the filter.
4. Install the T manometer, the assembling, the manometer and the air drain
plug. It is not necessary to use Teflon tape due to the imperviousness in this
point is made by the assembling. Not press the manometer with any tool, with
the hand is enough.
5. Clean the adjutage, the lid and the assembling recess of the silex residue and
close the filer. For more information see the filter manual.If the bin was jutting
out the pool water level you have to prime the pump, opening the prefilter and
filling with water until it been full.
If the bin is under the water level, it will be enough opening the inlet and outlet
cap, opening the air drain until the filter and the pump be full of water.
6. Put the caps in the following position:
SKIMMER
OPEN
CATCH BASIN
OPEN
POOL CLEANER
OPEN
COMING BACK
OPEN
SELECTOR VALVE
CLEANING
7. Starting the pump and effectuate a washing of the filter.
Make this operation of washing until you see the water clean and clear for the
selector valve finder.
8. Disconnect the pump.
Put the selector valve in rinsing position and activate the pump during 15
seconds. Stop the pump against and put the selector valve in filtration position.
9. Close the selector valve of the pool cleaner.
10. Activate the pump.
Note: Whatever manipulation whit the selector valve has to be realising
with the pump stopped if not it can damage the filter and the installation.
Put again the lid bin, fixing the back side with his correspondents bolts.
-IT IS RECOMMENDABLE TO PUT BREECHBLOCK OR A
LOCK SO AS TO THE CHILDREN AND NO AUTHORISED
PEOPLE CAN NOT ACCESS TO THE INTERIOR OF THE BIN.
THE PROGRAM OF FILTRATION. See programmer instructions in the interior of
the electrical board.
ONLY FOR MODELS WITH ELECTRICAL BOARD.
7
8
ATTENTION