DACE LUX DC12 Manual de instalación y uso - Página 2

Navegue en línea o descargue pdf Manual de instalación y uso para Abrepuertas de garaje DACE LUX DC12. DACE LUX DC12 12 páginas.

Table of Contents
1.0
Foreword
2.0
Disclaimer
3.0
Glossary
4.0
Technical Specifica ons
5.0
Parts Iden fica on
6.0
Assembling and Installing the Operator
5.1
Ver cal Mount Roll Up Drive Channel Posi on
5.2
A aching the Power Head to the Drive Channel
5.3
A aching the Cross Tube to the Drive Channel
5.4
Moun ng the Floa ng Bracket to the wall
5.5
A aching Door U-Brackets
5.6
Securing the Drive Channel to the Floor
5.7
Posi oning & Securing the Ba ery
7.0
Informa on before programming and commissioning the operator
8.0
Se ng the Physical Open & Close Limits
9.0
Programming the Operator
9.1
Programming Menu
9.2
Se ng the Open & Close Limits
9.3
Se ng the Opening & Closing Force
9.4
Enable or Disable Safety Beams
9.5
Se ng Auto Close
9.6
Se ng the Auxiliary Output
9.7
Enable or Disable Electric/Magne c Lock
9.8
Programming Remotes
9.8.1
Programming a Remote Bu on to Trigger the Operator
9.8.2
Programming a Remote Bu on to Turn the Operator Light On & Off
9.8.3
Erasing a Single Remote and its Bu ons from the Operator
9.8.4
Erasing All Remotes and their Bu ons from the Operator
9.8.5
Programming a Remote Bu on to set the Holiday Lockout feature
9.8.6
Factory Reset
10.
Advanced Controller Programming Op ons
10.1
Control Board Layout
10.2
External Trigger
10.3
Safety Beams
10.4
Electric and Magne c Locks
10.5
Auxiliary Status Output
10.6
Auxiliary Low Ba ery Output
10.7
Auxiliary Trigger Output
10.8
Auxiliary Light
11.
Connec ng a Solar Panel
12.
Error Codes
13.
Warranty
2
Page
ERROR
MEANING
CODE
3
4
bb
Beams Blocked
5
6
7
7
7
8
Lockout
LO
9
11
11
12
13
13
14
14
14
15
15
Encoder Stop
ES
16
(Fault/Obstruc on)
16
17
17
18
18
18
19
19
20
Error Programming
20
Er
Remote
21
21
22
22
22
23
Heavy Load
HL
26
Check Balance
Cb
CAUSE & REMEDY
Cause:
The infrared beam between the two Safety Beam sensors are blocked, indica ng
an obstruc on or the ba eries in the transmi er beam are low.
Remedy:
Remove anything that may be obstruc ng the doorway.
If there is no obstruc on, check that the Beam's wiring is correct.
Test the beams to ensure they are in fact opera onal.
Check for possible ant infesta ons in the beams.
If no beams have been installed, ensure that the beams se ng in the operator
menu is set to
bn
.
Cause:
The operator has been placed in 'Holiday Lockout' mode.
Remedy:
To deac vate Holiday Lockout, press the bu on on the remote that was assigned
to ac vate Holiday Lockout.
To prevent accidental ac va on, is it recommended that the func on is assigned
to a remote/s by pressing two of the remote bu ons simultaneously. This will
reduce the risk of accidentally ac va ng the Lockout func on.
Cause:
The operator has 'stalled'. This could be as a result of the door hi ng an
obstruc on, the limits being set incorrectly, an incorrect force limit se ng or a
faulty Encoder.
Remedy:
1) Remove any physical obstruc on. If no obstruc on....2.
2) Check that the limits have been set correctly and that the door is not stopping
hard against the floor or any other physical stop. If the limits are set
correctly.....3.
3) Check the Door Balance. To do this, disengage the door from the Drive
Channel via the Manual Release Mechanism. Be sure to support the door
before doing so to ensure that the door does not drop a er being released.
Manually open and close the door. The door should open and close easily,
requiring the same amount of force in both direc ons. If the door is difficult to
move in either or both direc ons, and the open and closing forces are not
within the opera ng parameters, the door will need to be balanced and
serviced. If the Door Balance is correct.....4.
4) The Force Level se ngs on the Control Board may need to be adjusted. This
may happen if the door is ageing.
5) If all the previous checks are in order the Encoder may be faulty and the
garage operator will need to be serviced.
Cause:
All 64 remote slots are occupied.
Remedy:
No further remotes can be programmed to the controller. In order to add new
remotes it will be necessary to delete some to make space.
Cause:
The operator has detected that the li ing force is greater than the allowed
maximum. This could be as a result of an increase in the door's fric on, incorrect
door specs or possibly a broken door spring.
Remedy:
Cau on: This error message indicates that the door is too heavy and that the
operator is unable to li it. Disengaging the the door from the Drive Channel via
the Manual Release Mechanism could result in the door dropping fast and could
cause damage or injury!
Disengage the door slowly and with great cau on. Manually open and closed the
door to establish the weight. If it is difficult to li , the door will need to be
repaired before reconnec ng it to the operator.
Cause:
The door has gone out of balance, usually as a result of either one or both of the
door torsion springs being broken.
Remedy:
Disconnect the door from the operator and open and close it manually. If moving
the door in one direc on is more difficult than the other direc on then the door
will need to be repaired before reconnec ng it to the operator.
23