3. A trained service professional should be
consulted to determine the extent of rota-
tion. Rotate the UV Shield to the desired
opened or closed position. Place one
hand on the Distal Cap and the other on
the Outer UV Shield. Rotate the Distal
Cap clockwise while rotating the Shield
counter clockwise until the desired posi-
tion is reached. Rotation will require firm
pressure.
Note: The CAP unit is designed to re-
quire firm pressure during rotation. Never
rotate the Ballast Cover and Distal Cap
simultaneously in opposite directions.
Doing so could possibly disassemble the
unit and void the warranty.
Be sure to insert the
Quad-Ion lamp with the
opening facing the air
flow.
4.
Note that the CAP System should be orientated with the "air flow" label run-
ning parallel with the length of the duct to ensure the four pins are in line with
the Four Pin Connector. Before inserting the CAP System, use a 1/4" hex
head screw driver to remove the four outer screws and pull off the Ballast
Assembly from the Retainer Ring. Remove the wax paper from the gasket
located on the bottom side of the Retainer Ring. Insert the Retainer Ring with
the Quad-Ion Lamp attached into the 4" hole, aligning the cross hairs parallel
to the duct. Press firmly on the Retainer Ring to adhere the gasket to the duct.
5.
Place Aluminum Tape Ring over Retainer Ring aligning the center. Firmly
press the Ballast Assembly onto the four pins protruding from the Quad-Ion
Cell Optional mounting configurations, such as opening the UV shields, may
vary the orientation of the "air flow" label. It's only intended to serve as a gen-
eral guideline.
Retainer Ring
Cross Hairs
Ballast Cover
Outer UV Shield
Duct
Quad-Ion Cell
Cross Hairs
Air Flow Label
8
Distal Cap
Pin Orientation
Ballast Assembly