AmerTac TE04WHB Manual de instrucciones y garantía

Navegue en línea o descargue pdf Manual de instrucciones y garantía para Timer AmerTac TE04WHB. AmerTac TE04WHB 3 páginas. 1-outlet digital timer

TE04WHB
Instruction Manual & Warranty
Indoor
1-Outlet Digital Timer
THIS TIMER IS FOR INDOOR USE ONLY – DO NOT USE IN WET
LOCATIONS.
THIS TIMER HAS A BUILT-IN RECHARGEABLE BATTERY THAT IS USED
TO RETAIN THE CURRENT TIME AND ON/OFF SETTINGS WHEN UNIT
IS NOT PLUGGED INTO AN OUTLET OR DURING POWER FAILURE.
Activating Timer
1. Display – Remove plastic display protection from front of display.
2. Installation – Plug timer into an outlet and wait for at least
30 minutes to charge the built-in rechargeable battery.
3. Set Current Time – While holding down CLK (Clock) button, press
DAY, HOUR and MIN (Minute) buttons respectively to set the weekday,
hour and minute. Note that AM or PM appears after the time.
Your timer is now ready to be programmed.
Programming Events
1. Press PROG button once, display will look as shown in Figure 1,
indicating ON programming of timer setting 1.
2. Press DAY button until the display shows the day(s) you want timer
to turn ON.
- All days of the week (MO TU WE TH FR SA SU)
- Any single day of the week (for example WE)
- Weekdays only (MO TU WE TH FR)
- Weekends only (SA SU)
3. Press HOUR and MIN buttons to select time of day to turn
timer ON – press HOUR button to change from AM to PM.
4. Press PROG button again, display will look as shown in Figure 2,
indicating OFF programming of timer setting 1.
5. Repeat steps 2 and 3 to set day(s) and time you want timer
to turn OFF.
6. To set additional ON/OFF cycles (maximum of 7 events) press PROG
button and follow procedures in steps 2 to 5 for each new ON/OFF
event. When finished, press CLK button – display will show current
time. Timer will control the device plugged into it according to the
programmed events.
Reviewing Events
Pressing PROG button to cycle through all programmed ON/OFF events.
Press CLK to return to normal operation.
Clearing Programmed Events
Press PROG button to locate the ON/OFF event to be cleared.
While holding MODE button down, press PROG to clear settings for
that event.
Activating Events
Automatic – For automatic operation of programmed events, press
MODE button until AUTO is displayed.
Random – For random operation, press MODE button until RDM is
displayed. Timer will turn ON and OFF at + /– 30 minutes of programmed
events randomly.
Manual – For manual operation, press MODE button until
ON (to turn and remain on) or OFF (to turn and remain off) is displayed.
Operating Timer
Plug timer into AC outlet. Plug lamp or appliance to be controlled into
timer. Check and adjust timer setting as required.
RATINGS:
125V~, 60Hz
8.3A, 1000W Resistive
8A, 1000W Tungsten
Not rated for ballasted lights.
For ballasted lights use Model TE55WHB.
MO TU WE TH FR SA SU
ON
Figure 1
MO TU WE TH FR SA SU
OFF
Figure 2
IMPORTANT NOTES
DO NOT EXCEED RATING OF TIMER – 1000 WATTS FOR RESISTIVE
LOADS AND 1000 WATTS FOR TUNGSTEN LOADS (SUCH AS LIGHTING).
Limited One Year Warranty
AmerTac™ warrants this product to be free from defects in material
and workmanship for a period of one year from the date of purchase.
AmerTac's obligations are limited to repairing or replacing any defective
unit and are effective only if such units are returned within one year
of the purchase date to AmerTac, 250 Boulder Drive, Breinigsville, PA
18031. Warranty void if damage is due to misuse or improper installation.
In no circumstance will AmerTac be liable for consequential or incidental
damages relating in any way to this product.
Questions?, ¿Preguntas? 201.661.9945
©2011 AmerTac™
Saddle River Executive Centre,
One Route 17 South, Saddle River, NJ 07458
www.amertac.com
Made in China