Testing 12VDC Batteries
1.
Set the Mode Switch to Audible.
2.
Remove Probe Caps from Test Probes.
WARNING! TO PREVENT SERIOUS
INJURY: Removing Probe Caps
reduces safety to CAT II.
Testing 120VAC GFCI Outlet
can cause death or injury! Do not touch Probes while Tester in use.
Hold Probes by insulated handles, behind Protection Guards. If
circuit fails any test, have it serviced by qualified electrician.
1.
Check instructions on the
specific GFCI device you are
testing before proceeding.
2.
Set the Mode Switch to GFCI Test.
3.
Remove Probe Caps from Test Probes.
WARNING! TO PREVENT SERIOUS
INJURY: Removing Probe Caps
reduces safety to CAT II.
Page 6
TO PREVENT SERIOUS INJURY: Electrical shock
Neutral
For technical questions, please call 1-888-866-5797.
3.
Put one Probe on each post of battery.
4.
12V LED should light up
if voltage is present.
4.
Test GFCI Outlet:
a. Put Black Probe into Ground
receptacle first, then put Red
Probe into Hot receptacle.
b. 120 LED will light up if
voltage is present.
c. Press Test button, 120 LED will
go out. If 120 LED does not go
out, have GFCI Outlet replaced
by qualified electrician.
d. Press Reset button,
120 LED will light up.
e. Remove Probes.
Hot
Ground
RESET
TEST
Item 58447