COHERE maxem Manual de instalación - Página 5
Navegue en línea o descargue pdf Manual de instalación para Domótica COHERE maxem. COHERE maxem 17 páginas.
Preparation
01 - Voorbereidingen vooraf
Environmental Requirements
•
Free space for Maxem with connected wiring at the bottom.
•
Free Schuko 230V socket on Phase 1 (L1) for feeding Maxem or free space to place a
new one.
•
Free Ethernet port for Internet connected modem or router.
•
An UTP cable must be pulled (or already be available) from Maxem to the charging
station.
A
184mm
A
55.50
167
SECTION A-A
55,50mm
Default length tolerances: DIN 7168
Client:
Date:
Sheet:
A3
Dim.:
0-6
7-30 31-120
121-400
401-1000
Cohere
17-02-2016
1/2
Tol.:
±0,1
±0,2
±0,3
±0,5
±0,8
Drawn:
Material:
Vol. (mm³):
Scale:
Units:
Default angle tol.:
Default edges:
MH
-
-
1:1
mm
±20'
<0,2x45° or R<0,2
Drawing name:
File reference:
Rev. nr:
Roughness:
Finish:
Ra 0,8 um
Maxem 4 Assembly
CES-01 - Enclosure
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
Necessary tools
•
Crosshead screwdriver, size small.
•
Flathead screwdriver, size mini < 3mm.
•
Flathead screwdriver size large.
•
RJ45 (8P8C) crimping pliers.
•
RJ10 (4P4C) crimping pliers.
•
Cable Tester for UTP cables.
Necessary materials
•
A correct circuit breaker or earth leakage circuit breaker with proper fusing value.
p. 10 to determine fusing.
•
Schuko sockets for 230V power supply Maxem (if not already available.
•
UTP (CAT5 or CAT6) data cable for connecting charging station to Maxem.
•
RJ45 (8P8C) connectors for UTP cable.
•
Cable end sleeves for UTP cores (only for Tesla Wall Connector or EV-Box).
8
20mm
20mm
20mm
Wiring at the bottom
70mm
See
Wired Internet access
Maxem must be connected to a wired Internet connection. The following is needed:
•
Modem or router connected to Internet.
•
A DHCP connection from the network to Maxem.
•
Maxem should be able to do DNS requests.
•
Maxem may also be placed in a DMZ (demilitarized zone) on a separate VLAN.
Compatible with Maxem charging stations
ICU Twin
ICU EVe
ICU EVe mini
Tesla Wall Connector
EV-Box Business
(G3 controller)
Tesla Wall Connector itself does not measure current, for this a MID kWh-meter is
needed. It can be supplied with Maxem.
KEBA P20/P30
ICU Compact
EV-Box Home
(G3 controller)
9