Compare the value showing on the Resistance Out switches to the values in the
6.
Resistance Out Range column in Table 2.
a.
If the switch value does not fall within the range in the Resistance Out
Range column, or if the gauge does not function as described, replace it.
b. If the gauge is functioning properly, refer to AMETEK Dixson Product In-
formation Note 072-40286 (Troubleshooting Fuel Gauges) for trouble-
shooting tips.
Table 2
Resistance Out Values
The following example will help you understand this procedure:
The scale plate on a suspect temperature gauge reads from 100 to 300 degrees Fahrenheit.
You connect the PST-2000 to the gauge and configure the Resistance Out switches to posi-
tion the pointer to 200 degrees after tapping the gauge. If the gauge is accurate, the value
showing on the Resistance Out switches will be between 103 and 119 ohms as shown in
Table 2.
11 Ammeter
Unplug the gauge to be tested and connect the PST-2000 as described in Figure 2.
1.
Turn the PST-2000 Input Voltage switch to either 12 volts or 24 volts, whatever is
2.
appropriate for your vehicle.
Turn the ignition on.
3.
a.
If the green Battery Voltage LED is on, continue this procedure.
b. If one of the red LEDs is on, the Input Voltage switch may not be set to
the vehicle's battery voltage, or the battery voltage is too high or too low.
072-40236-B
Using the PST-2000 with Freightliner Trucks
Scale Plate
Gauge Test
Type
Points
100 to 350° F
150°
300°
100 to 300° F
200°
250°
100 to 260° F
140°
200°
100 to 250° F
150°
200°
Fuel Level
Full (F)
Empty (E)
Resistance Out
Range
170 to 186 ohms
34 to 50 ohms
103 to 119 ohms
59 to 75 ohms
220 to 236 ohms
80 to 96 ohms
188 to 204 ohms
79 to 95 ohms
26 to 40 ohms
220 to 260 ohms
Page 9 of 10