Ametek Gemco 952CP Ram-Set Manual de instalación y mantenimiento - Página 18

Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Controlador Ametek Gemco 952CP Ram-Set. Ametek Gemco 952CP Ram-Set 20 páginas. Automatic press shut height controller

Note: Malfunctions due to the above can usually be cleared by removing, and then reconnecting power to the control-
ler. The cause of such problems can be determined and eliminated. If removal and reconnection of power does not
correct the problem, a controller failure has occurred. If the outputs are operating properly, the failure is most likely in
the display section. If outputs do not operate properly, the failure is most likely in the CPU section.
Chapter 5: Programming and Function Charts
Password
Function
Number
1
Program new die #'s and positions
753
Clear all die #'s and positions
8
System offset
9
Transducer calibration (wire speed)
10
Up/down counting direction
11
Slow-down entry point
12
Upper limit
13
Lower limit
14
Time-on for slow dwell
15
Time-off for slow dwell
16
Trouble fl ags
17
Review all programmed dies & positions
18
Ram "In Position" window
19
Software number
Software number
Software number
21
Inches/mm
100
Remove a specifi c die # and position
200
Counter balance override
268
Diagnostics (Function #268)
391
Initialization
555
Jogging with system errors (Function #555)
Note: If an attempt is made to enter too large a value, the display will show EEEEE4. If this value is too small, the
display will show EEEEE3. Example: Entering a ram position outside of the upper and lower limits.
Initialization
Description
Installation and Maintenance Manual
Chapter 4: Maintenance and Trouble Shooting
Value
N/A
N/A
48 In. Max. Pos.
9.040 in/sec.
0 (Up)
0.050 inch
48.999 inch
0.000 inch
0.40 sec.
0.40 sec.
N/A
N/A
.010 inch
N/A
1
N/A
0
N/A
N/A
N/A N/A
Range
Up to 5 digits
N/A
0 to 99.999 inch
1.000 to 65.000 in/sec.
0=Up; 1=Down
0 to .259 inch
0 to 48.999 inch
0 to 24.999 inch
0 to 9.99 second
0 to 9.99 second
N/A
N/A
0- to .099 inch
N/A
0 or 1
N/A
0 to 15
N/A
N/A