Coldtainer F0140/NDH Manual del usuario - Página 6

Navegue en línea o descargue pdf Manual del usuario para Frigorífico Coldtainer F0140/NDH. Coldtainer F0140/NDH 16 páginas.

Coldtainer F0140/NDH Manual del usuario
any hot item inside the unit, precool them first.
IMPORTANT: the starting current of the larger BD compressor can reach 35A (12V).
To guarantee stable operations it is essential to connect the units to batteries of
proper Ah capacity.
In case of the larger freezer versions it is recommended to use batteries with no less
than 100Ah (with150A alternators) capacity.
In case of use of a too small Ah capacity battery, even if new and well charged, the
compressor would not start. This is valid also for connection of multiple units to a
same battery.
Eventually connect the unit to a proper capacity deep cycle service battery, using a
proper split charging system to connect it to the main battery.
Even if the plastic materials (PE) used for the production of the units are food grade,
it is always suggested to store food or other products in proper closed containers.

BEFORE USE

The units should be placed in a dry location and should not be exposed to di-
rect sun light or any other heat source (e.g. radiator). Protect it against rain and
humidity. In case on use on a pick-up truck, always use a proper cargo cover to
protect the unit.
Always make sure there is sufficient ventilation so that heat generated during
normal operation can dissipate. Ensure that the ventilation slots are not cove-
red. Leave at least 50 mm. from top and around the unit to grant an adequate
ventilation.
Always secure tightly the units f loaded on a vehicle, in order to prevent any
forward, side and backward movement during driving or while braking. Use
load straps, anchor points or other suitable restraints, properly homologated.
Store the items within the fridge so that the air can circulate around the goods.
Do not open the fridge more often than necessary and do not leave the
lid / door open for longer than necessary.
Take care when transporting pharmaceuticals and biological products. Always
check if the temperature range of the fridge is adequate for the purpose.
All servicing and repairs involving recharging of the cooling system must only
be carried out by a qualified customer service engineer.

ELECTRICAL CONNECTIONS, STANDARD MODELS

The c
oldtainer
sources:
12Vdc or 24Vdc (the input voltage is automatically regulated by the electronic):
T0022/FDN, T0022/FDH, T0032/FDN, T0032/FDH, T0056/FDN, T0056/FDH,
T0082/FDN, T0082/FDH, F0140/NDN, F0140/NDH, F0140/FDN, F0140/FDH,
F0330/NDN, F0330/NDH, F0330/FDN, F0330/FDH, F0720/NDN, F0720/NDH,
4
s can be operated connected to following direct current power