3. Product description
3.1 Funktionsbeschreibung
The ED 100 and ED 250 are electromechanical automatic
swing door drives. They automatically open swing doors once
an activator has been activated.
The door closes after the set hold-open time has lapsed.
If a suitable locking device is connected, it will be opened by
the movement of the door.
In case of a power failure, people can pass through the
door at any time; the drive will then work like a normal door
closer.
Functions
The drives feature 4 different functions. The functions can
be selected on the program switch.
Funktion
Meaning
OFF
The door will be automatically opened once
the activator Night/Bank has been activated.
The door closes when the open-hold time
night/bank has ended.
AUTOMATIC
The door will automatically open once an
activator has been activated.
The door will close again once the set hold-
open time has expired.
PERMANENT
The door will automatically open and stay
OPEN
open as long as the function is activated.
EXIT ONLY
The door will automatically open only after
the inside activator or the activator Night/
Bank has been activated.
The door will close again once the set hold-
open time has expired.
3.2 Operating elements
The power switch is always on the door hinge side; the
internal program switch is always on the side of the main
closing edge.
Power switch
Power switch
Program switch
Use the program switch to select the function. The program
switch can be a 4-digit or 3-digit type.
In case of an internal, 3-digit program switch, the function
EXIT ONLY is not available for 2-panel systems.
Internal program switch
In order to select the function, you must set a combination
of both rocker switches on the internal program switch.
OFF
Both switches are set to "0".
AUTOMATIC
The front switch is set "0",
the rear switch is set to "I".
PERMANENT OPEN
The front switch is set to "0",
the rear switch is set to "II".
EXIT ONLY
(only for 1-panel systems)
The front switch is set to "I",
the rear switch is set to "I".
External program switch
On the external program switch, the function is selected by
pressing the corresponding pushbutton.
PERMANENT OPEN
Internal program switch
3.3 Technical data
Ambient temperature
Relative air humidity
Power supply
Protection class
Fuse protection provided by
the customer
Operating noise
ED 250
Max. power input
Closing force
Door panel width
Internal program switch
ED 100
Max. power input
Closing torque EN 1154
Door panel width
1
Off
2
AUTOMATIC
3
EXIT ONLY
4
5
without function
ERROR
-15 – +50 °C
Max. 93 %
non-condensing
230 V AC +10 % / -15 %,
50 Hz
IP 20
16 A
Max. 50 dB(A)
240 Watt
EN 4 – 6 infinitely variable
700 – 1,600 mm
120 Watt
EN 2 – 4 infinitely variable
700 – 1,100 mm
1
1
2
4
3
2
4
3
5
3