Dormakaba UNIQUIN Manual - Página 3
Navegue en línea o descargue pdf Manual para Unidad de control Dormakaba UNIQUIN. Dormakaba UNIQUIN 12 páginas. Door closer system
También para Dormakaba UNIQUIN: Instrucciones de montaje (8 páginas)
dormakaba System manual
1.4
Symbols used
1.4.1
Safety instructions
Safety instructions are marked with symbols. The
safety instructions are introduced by signal words
that express the extent of the hazard, e.g.:
WARNING
This signal word indicates a possible
hazardous situation which may result in
death or serious injury if ignored.
CAUTION
This signal word indicates a situation of
potential risk, which could lead to minor or
slight injury if not averted.
ATTENTION
This signal word indicates a situation of
potential risk, which could lead to damage to
property or the environment if not averted.
TIPS AND RECOMMENDATIONS
This signal word indicates useful information
for efficient and trouble-free operation.
1.4.2
Further labeling
1.
2.
Step-by-step graphics
Position numbers for parts
1
2
in diagrams
2 Safety
2.1
Intended use
The product is designed to create a partition between
spaces or areas inside a building by connecting to the
wall and ceiling.
The product may only be used with system
components made by dormakaba specifically for the
UNIQUIN system.
Installation must be carried out according to the
enclosed installation manuals.
• Only tempered safety glass (TSG) or laminated
safety glass (LSG) made of TSG may be installed
with the product.
• dormakaba can provide a general certificate of
structural stability for the UNIQUIN units.
UNIQUIN System
• The use of other composites must be checked by the
• The product may only be attached to a surface
• The product is only suitable for indoor use.
• The product is suitable for use in tropical countries.
• It is possible to have an emergency exit in
2.2 Foreseeable misuse
The product is not suitable for installation in the
vicinity of showers, saunas, swimming and salt-water
bath or rooms in which chemicals (e.g. chlorine) are
used.
Fig. 1
WN 059609 45532
designer or contractor and the structural stability
assured if applicable.
capable of bearing loads using suitable fixing
materials.
accordance with EN 179, EN 1125 with certain
product combinations.
WARNING
Danger to life due to falling glass.
Falling glass can lead to life-threatening
injuries.
• Glass should not be suspended.
• Mount glass with at least 2 persons.
• Secure glass using the correct methods.
• Follow correct installation sequence.
• Clamping profiles on the base profile are
not load-bearing.
CAUTION
Risk of injury from falling to a lower floor.
The failure of the unit e.g. through broken
glass, can lead to personal injury, as people
could fall to a lower floor.
• The unit must not be installed as fall
protection in places where there is a risk
of falling to a lower floor.
ATTENTION
Risk of damage due to eccentric vertical
load.
Attaching eccentric vertical loads to the
product can cause damage.
• Do not attach any eccentric vertical loads
to the product, e.g. by building shelves.
Not suitable for showers, saunas, baths or salt-water
baths
Safety
2018-12
3