Dormakaba 8900 PT Manual de instrucciones de instalación - Página 7
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Sistema de interfono Dormakaba 8900 PT. Dormakaba 8900 PT 8 páginas. Emf surface applied closer (no detector)
También para Dormakaba 8900 PT: Manual de instrucciones de instalación (10 páginas)
dormakaba 8900 PT/PTH Installation Instructions
3.3 Adjust spring force
Fig.7
Track mount
8916
8956
4
Install covers
Fig.8
4.1.1 Place tab in cover slot, opposite main
arm.
4.1.2 Place cover over closer and fasten
securely with screws provided.
8900 Surface Applied Closers
8916 - supplied with a size 3
8956 - supplied with a size 6
Increase
8916 ONLY - Barrier free openings: Take an opening
Decrease
force reading from the pull on the door. If required,
adjust the spring force to meet the barrier-free
requirement.
•
•
Depending on opening conditions, a door adjusted to
meet barrier-free forces may not have sufficient power
to reliably close and latch the door.
Door width
Max door
Closer size
weight (lbs)
Interior
4
125
2'-6"
5
150
3'
6
200
3'-6"
6
200
3'-6"
6+
250
4'
LH
08279731
Decrease force: turn counter-clockwise; 8 turns max.
Increase force: turn clockwise; 14 turns max.
Full turns
0
+8
+16
0
+6
Adjust spring force
Secure covers
Snap valve
adjustment
wrench inside
cover.
09-2019
7