CANTERBURY Officina Nicolazzi Classic Prov Z2625 Manual de instrucciones - Página 7

Navegue en línea o descargue pdf Manual de instrucciones para Cocina & Accesorios de baño CANTERBURY Officina Nicolazzi Classic Prov Z2625. CANTERBURY Officina Nicolazzi Classic Prov Z2625 9 páginas. Exposed shower lever handle

Care and Maintenance Instructions Model : Z2625
MAINTENANCE FOR WALL MOUNTED TWO LEVER TAP WARE
INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or
kinking of supply hoses.
 Turn off the hot and cold supply lines to the tap set.
If the hand spray is leaking, do not replace the diverter. Service or replace the hand
(Not shown).
 Remove the handle. Refer to "Removing and
spray if there is a continous leak.
replacing a handle" section, page6.
 Unscrew and remove tap cover cap C.
 Install new cartridge.
 Secure the cartridge with a smooth jawed shifter.
Note: Do not over tighten as this could damage the ceramic cartridge!
Further information Phone (03) 9761 4603
7
Remove the cartridge with a 17mm spanner or
smooth jawed shifter.
 Install the handle and retaining flange, and hand
tighten only. DO NOT USE A SHIFTER TIGHTEN BY
HAND ONLY!
 Turn on supply line and test for leaks. (Not shown).