8 MAINTENANCE AND END-OF-LIFE
Before carrying out any maintenance operation, it is obligatory to disconnect the power sup-
ply cable from the main socket and to aerate the premises in which it is installed for at least 15
minutes. Complex or long maintenance operations must be done out of fuel storage and heating
unit premises.
Any maintenance and repair operation must be carried out by experienced personnel and au-
thorized by the manufacturer.
In the absence of a specifi c maintenance plan, a complete product inspection is recommended for each
fi lling of the fuel storage tank.
The checks to be carried out at least monthly are:
- Check the electrical wiring condition
- Verify the motor brushes condition
- Eliminate dust traces from the mesh fi lter located inside the dispenser
- Clean the rubber interior part of the fuel discharge door
It is also advisable to thoroughly clean the fuel storage tank at least annually, in order to avoid dust
accumulation and presence of foreign bodies.
8.1 Spare parts
To guarantee longevity and optimum performance of the vacuum unit, it is recommended to use
only original spare parts.
SPARE PART DESCRIPTION
0-1 switch
Circuit board
Motor
Motor Brushes
Thermal switch
Reed Microswitch
Discharge door with magnet
Mesh fi lter
8.2 End-of-life
The disposal of packaging, accessories and machine must be executed in accordance with applicable
laws, ensuring the recycling of any of the core components.