(1) 3 Minutes Compressor Delay Mechanism
To avoid any damage to the dehumidifier, the dehumidifier will not start operation
following a complete cycle until after 3 minutes. Operation will automatically start after 3
minutes. In other word, if you turn the dehumidifier off and then restart it immediately,
the compressor will not kick in until 3 minutes later. During this period, you can see the
RUNNING icon flashing on the LCD screen until the compressor kicks in.
(2) Auto Defrost
When the frost builds up on the evaporator coils, the compressor will cycle off and the fan
will continue to run until the frost disappears. When the dehumidifier is defrosting, you
can see the DEFROSTING icon light up on the LCD screen.
(3) Auto-Restart
If the dehumidifier shuts off unexpectedly due to power outage, the dehumidifier will
restart with the previous function settings automatically when the power resumes.
(4) Temperature Protection Function
When the room temperature is higher than 113°F,the dehumidifier will automatically
enter into HIGH-TEMPERATURE PROTECTION SYSTEM where the LCD screen displays an "HH"
message and the compressor stops.
When the room temperature is lower than 40°F,the dehumidifier will automatically enter
into LOW-TEMPERATURE PROTECTION SYSTEM where the LCD screen displays an "LL"
message and the dehumidifier stops working.
Note: When you see HH or LL message under normal circumstances, please contact the
customer service at [email protected] to get technical support.