Colzer PD223A Manual del usuario - Página 18
Navegue en línea o descargue pdf Manual del usuario para Deshumidificador Colzer PD223A. Colzer PD223A 20 páginas.

『TROUBLE SHOOTING』
1. Error Codes
Error Code
Problem
E1
Humidity Sensor Malfunction
E2
Defrost Temperature Sensor
Malfunction
E4
Ambient Temperature Sensor
Malfunction
Water bucket is full.
E7
The water bucket has not been
installed properly.
Float Malfunction
Note:
When E1, E2, or E4 error displays, you can hear an alarm that could last 15 seconds. In this case, the
dehumidifier is still running. You can follow the below steps to eliminate the error message:
· Pressing any button on the control panel to eliminate the alarm.
· Turn off the dehumidifier and unplug it to check if any obstructions.
· Restart the dehumidifier 10 minutes later..
If the ERROR message does not disappear after the restart, immediately contact COLZER customer
service at [email protected].
2. Reset
Please try the below steps to reset the dehumidifier if necessary:
1) Turn the dehumidifier off;
2) Press and hold the LIGHTING button for 5 seconds, until dF flashes on the LCD screen;
3) Press the MODE button once;
4) Wait for 5 seconds to let the system auto-reset to default settings.
3. Trouble Shooting
The below chart will help you solve common problems that may occur. If the problem you come
across can not be fixed after troubleshooting or the problem is not listed in the below
troubleshooting chart, please contact COLZER customer service to obtain professional support at
Solution
1. Check the humidity sensor and ensure it is
in good condition.
2. Replace the humidity sensor.
1. Check the temperature sensor and ensure
it is in good condition.
2. Replace the temperature sensor.
1. Check the temperature sensor and ensure
it is in good condition.
2. Replace the humidity sensor.
Empty the water bucket.
Re-install the water bucket properly.
Replace the float of the water bucket.
14