Baumer CombiTemp TFRH Manual de instrucciones - Página 2

Navegue en línea o descargue pdf Manual de instrucciones para Accesorios Baumer CombiTemp TFRH. Baumer CombiTemp TFRH 12 páginas. Temperature sensor

Baumer CombiTemp TFRH Manual de instrucciones
English page 1 ... 7
Mechanical specifications
Sensor tube and
process connection
Stainless steel, AISI 316L (1.4404)
Housing
Stainless steel, AISI 304 (1.4301)
Mounting part
Stainless steel, AISI 304 (1.4301)
Electrical connection
Plug
Material
Cable gland M16 or M20
Material
Environment
Process pressure
≤40 bar (60 bar)
Process temperature
-40 ... 250 °C (see page 3)
Ambient temperature
-50...160°C without transmitter / display
-40...85°C with transmitter only
-30...80°C with transmitter and display
Humidity
<98% RH, condensing
Protection class
IP67/IP69K
Vibrations
GL, test 2 (sensor tube <200 mm)
CombiView DFON display
Type
Graphically LCD
Front glass
Polycarbonate
Display modes
8 modes, programmable
e.g. value, bar graph, analogue
Background colour
White, green, red - programmable
Measuring range
-9999...99999
Digit height
Max. 22 mm
Accuracy
0,1% @ ambient –10...70 °C
0,2% @ ambient –30 ... -10 / 70 ... 80 °C
Voltage drop
4V...6,5V - depending on background light
Output
2 configurable relay output, 60 Vp, 75 mA
Programming
Touch screen or FlexProgrammer 9701
Further information can be found in separate data sheet and/or operat-
ing instructions for the Baumer graphical display, CombiView DFON.
www.baumer.com
M12, 5-pin or 8-pin
Stainless steel AISI 304 (1.4301)
Plastic or
Stainless steel AISI 304 (1.4301)
Operating Instructions: 11163172 06 EN
Temperature sensor
CombiTemp TFRN/TFRH
Operating instructions
Sensor element specifications (DIN/EN/IEC 60751)
Sensor element
Pt100
Accuracy
Class B
(sensor element)
Class AA
-
1/3 B
-
1/6 B
Class A
Single element
1 × Pt100
Double element
2 × Pt100
Connection
2-wire or 4-wire
®
FlexTop
2202 temperature transmitter
Input
Pt100
Output
4...20 mA
Accuracy
input < 0,25°C, span ≤ 250 °C
-
output < 0,1% signal span (16 mA)
Range
-200...850°C
Minimum span
25°C
Voltage supply range
8...35 V DC
Programmability
By FlexProgrammer 9701
Further information can be found in separate data sheet and/or operating
instructions for FlexTop 2202
®
FlexTop
2211 and 2221 temperature transmitter
Input
Pt100
Output
2211 4...20 mA
2221 4...20 mA / HART
Accuracy,
input <0,1°C
output <0,1% signal span (16 mA)
Range
-200...850°C
Minimum span
25°C
Voltage supply range
2211 6,5 ... 30 V DC
2221 8,0 ... 35 V DC
Programmability
By FlexProgrammer 9701
Further information can be found in separate data sheet and/or
operating instructions for FlexTop 2211 or FlexTop 2221
±(0,3 + 0,005×t)°C
±1/3 × (0,3 + 0,005×t)°C
±1/3 × (0,3 + 0,005×t)°C
±1/6 × (0,3 + 0,005×t)°C
±(0,15 + 0,002×t)°C
< 0,1% span, span > 250 °C
Page 2 / 12