Baumer Hubner GT 9 Instrucciones de montaje y funcionamiento - Página 26

Navegue en línea o descargue pdf Instrucciones de montaje y funcionamiento para Accesorios Baumer Hubner GT 9. Baumer Hubner GT 9 28 páginas. Tachogenerator

9

Technical data

9
Technical data
9.1

Technical data - electrical ratings

• Reversal tolerance:
• Linearity tolerance:
• Temperature coefficient:
• Isolation class:
• Calibration tolerance:
• Climatic test:
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
• Interference immunity:
• Emitted interference:
• Approval:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Protection DIN EN 60529:
• Torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Weight approx.:
• Connection:
23
≤0.1 %
≤0.15 %
±0.05 %/K (open-circuit)
B
±5 %
Humid heat, constant
(IEC 60068-2-3, Ca)
0.3 W (speed ≥5000 rpm)
):
<9 µs
A
10...20 mV per rpm (as ordered)
EN 61000-6-2
EN 61000-6-3
CE
ø89 mm
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
IP00, IP44 (with cover)
0.35 Ncm
0.95 kgcm
2
Housing: stainless steel / plastic
Shaft: stainless steel
-30...+130°C
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
0.6 kg
Plug-in terminals
Baumer_GT9_II_DE-EN (19A1)
MB023 - 11055627