Baumer IO-Link RR30 Manual de instrucciones - Página 10

Navegue en línea o descargue pdf Manual de instrucciones para Accesorios Baumer IO-Link RR30. Baumer IO-Link RR30 40 páginas. Radar sensor

Baumer IO-Link RR30 Manual de instrucciones
4

Parameter

RR30 Radar sensor are available in three different distance versions (6, 12 and 60 m). Therefore all allowed
or default values in list of this chapter will have three different values according to one of the versions.
wo= write only, ro= read only, rw= read and write

4.1 System Commands

A factory reset of the sensor activates the default parameters as set in the factory. All parameters changed
by the user will be lost.
Parameter name
Standard command

4.2 Measurement Data Channel (MDC)

Measurement Value Distance

4.2.1
Parameter name
Measurement Value.
Distance

Switch Counts

4.2.2
For each individual SSCx a switching counter is implemented. The number of counts of each channel can
also be mapped to the measurement data channel MDC by adjusting the MDC source. The Trigger of the
counter is on the positive slope of the elated SSC.
Parameter name
-
SSC1 Switch Counts
Reset
-
SSC2 Switch Counts
Reset
-
SSC4 Switch Counts
Reset
-
Switch Counts.SSC1
Resettable
-
Switch Counts.SSC2
Resettable
-
Switch Counts.SSC4
Resettable
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Restore Factory Settings
Short Description
Process value for distance
Short Description
Command to set the counter value of
the SSC to zero
Total number of switch counts on
SSC1 (resettable by user command->
SSC1 Switch Counts Reset)
Available for SSC1,2 and 4.
10/40
Rights
Unit / Allowed
values
wo
Rights
Unit / Allowed
values
mm
ro
Rights
Unit / Allowed
values
wo
32 Bit value
ro
Baumer Electric AG
Frauenfeld, Switzerland