Parameter name
Region of Interest.Start
Distance
Region of Interest.End
Distance

4.7 Expert settings

The following parameters are specific for this type of Radar sensors and are used to optimize the
performance of the sensor.
The table gives an overview of all expert settings parameters, while being followed by more detailed
explanations. After a profile is chosen the following procedure usually applies:
-
Adjust the sensitivity level
-
Choose the peak settings depending on respective environment
-
Adjust filters (Exponential Output / Disruption )
Parameter name
Measurement Sensitivity
Scale
Peak Setting Mode
Operation Modes
Measurement Modes
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Defines the Start of the Region
of interest within a signal
becomes visible at the output.
Defines the End of the Region of
interest within a signal becomes
visible at the output.
Short Description
Select sensitivity level in 5
different scales from Very Low
to Very High.
Peak selection for the output
value calculation.
Algorithm selection for the peak
calculations.
23/40
Rights
Unit / Allowed values
Limits:
rw
- 100 to 8500 mm
(Vers.: DAF0)
- 100 to 15500 mm
(Vers.: DAJ2)
- 100 to 82000 mm (Vers.:
DAO0)
Default = 100 mm
Limits:
rw
- 100 to 8500 mm
(Vers.: DAF0)
- 100 to 15500 mm
(Vers.: DAJ2)
- 100 to 82000 mm
(Vers.: DAO0)
Default =
- 6500 mm (Vers.: DAF0)
- 12500 mm (Vers.: DAJ2)
- 62000 mm (Vers.: DAO0)
Rights
Unit / Allowed values
rw
- Very High
- High
- Medium (Default)
- Low
- Very Low
rw
- Highest Peak
- First Peak (default)
- Second Peak
- Last Peak
rw
- Fast
- Precise (default)
- Structured
- Precise – all