Symptom
Heater Platen overheating
Dough not having same thickness
across the press dough.
DOUGHPRO
DP2000 Trouble Shooting Guide
Probable Cause
If the Relay (depending the year of
the model) on the coil side are
receiving 12vdc indicates the
Controller is functioning properly. On
the switching side of the relay, is
there 120 vac going to the heater in
question . If there is no voltage on
the to the switching side of the relay
to the heaters, the Relay is not
working properly. It has been seen
on remote cases, the Sensor (2M
ohm) can give a false reading as well.
To adjust upper platen for level press Underneath the arm resting on the
Action to be Taken
Replace Relay If the Controller's heat-
on LED is not lit indicating the
controller is working properly. If this is
not the issue, replace sensor.
Upper Platen Shroud you will find 4,
stacked hex bolts sitting over the upper
platen attach to the arm. The top bolts
are called locking bolts. The 4 larger
Hex Bolts below are Adjustment Bolts.
Break free the 4 Locking blts. With a
open end wrench adjust the A. bolts
(1/8 turn at a time where needed and
test with dough. After satisfied,
tighten the Locking bolts making sure
not to move the larger Adustment
Bolts.