Baumer HMG 10-SSI Manual de instrucciones de instalación y funcionamiento - Página 13
Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para Media Converter Baumer HMG 10-SSI. Baumer HMG 10-SSI 36 páginas. Absolute encoder with magnetic sensing
![Baumer HMG 10-SSI Manual de instrucciones de instalación y funcionamiento](/uploads/products/server2/1259650/1259650.jpg)
)
4.3.2
Version with cone shaft
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
MB244EN - 11171691, 16A3, Baumer_HMG10-SSI_II_EN
12�
10b
10c
10a
5
10e
10d
MOUNTING / MOUNTING TO DRIVE SHAFT
10c 10b
10b
9
10c
1�6x8 mm
17 mm
7a
11b
11a
Mt = 3-4 Nm
10 mm
section 4.5,
TX 20
2
3
5 mm
9/32