6.4.5.

Parameter 925: Tolerated life sign failures

Read: The parameter is to read the number of tolerated Master life sign failures.
Only profile 3.1 will consider this parameter. When running profile no. 4.1,
the number is always 1.
Parameter
Type
Data type
Value range
Data: 925[0]
Write: The parameter is to read the number of tolerated Master life sign failures.
Only profile 3.1 will consider this parameter. Where running profile no. 4.1.,
the number is always 1.
Parameter
Type
Data type
Value range
Data: 925[0]
Note:
In "Compatibility Mode", only the user-specific parameter of the project HW configuration will be
considered. Parameter 925 is of no significance.
6.4.6.

Parameter 964: Device ID

Read: This parameter is to read a data set for encoder (device) identification.
See also parameter 975.
Parameter
Type
Data type
Value range
Data: 964[0]
964[1]
964[2]
964[3]
964[4]
964[5]
6.4.7.

Parameter 965: Profile ID

Read: This parameter is to read the profile ID=0x3D00 of encoder profile 3162 in abbreviation „3D"
as well as the applicable (configured) version V3.1 or V4.1.
Parameter
Type
Data type
Value range
Data: 965[0]
965[1]
Baumer_BUDE-PROFINET_MA_EN.docx
14.06.2016 / bja
925
Read / Write
unsigned int (0x06)
1 to 254; 255=Life sign Supervision 0ff
Total number of tolerated life sign failures
925
Read / Write
unsigned int (0x06)
1 to 254; 255=Life sign Supervision 0ff
Total number of tolerated life sign failures
964
Read only
unsigned int (0x06)
n/a
0x012A
MANUFACTURER_ID
0x0000
Drive Unit Type (manufacturer-specific)
0x0210
Firmware version (example only)
0x2015
Firmware year (example only)
0x1103
Firmware day and month (example only))
0x0001
Number of Drive Objects
965
Read only
Octet string (0x0A)
n/a
0x3D
Profile ID: 0x3D
0x29 or 0x1F
Profile version: V3.1 (31) or V4.1 (41)
33/41