13

Technical data

13.1

Mechanical data

Size (flange)
Shaft
Bore runout
Admitted misalignment
Protection DIN EN 60529 IP 54, IP 65, IP 67
Operating speed
Bearing
Starting torque
Rotor moment of inertia
Service life
Materials
Operating temperature
Relative humidity
Resistance
Connection
Weight approx.
Baumer_HS35_II_DE-EN_1706.indd
ø3.15" (ø80 mm)
ø0.375...1" (ø9.525...25.4 mm)
through hollow shaft isolated
0.0016" (0.04 mm) TIR max.
0.004" (0.1016 mm) radial TIR (end of shaft)
0.01" (0.254 mm) axial
≤5000 rpm (see temperature diagram on page 43)
52100 SAE high carbon steel (ABEC 5)
≤3 in-oz (77 °F, IP 65)
≤0.02 Nm (+25 °C, IP 65)
2.3 oz-in² (420 gcm²)
Bearing: typ. 13 billion rev.
(89000 h / 2500 rpm)
Housing: aluminium, powder-coated
Shaft: stainless steel
-40...+212 °F (-40...+100 °C) (fixed cable): see
temperature diagram on page 43
98 % non-condensing
DIN EN 60068-2-6
Vibration 20 g, 55-2000 Hz
DIN EN 60068-2-27
Shock 200 g, 6 ms
MIL-connector, 7-pin (not for HS35S)
MIL-connector, 10-pin
Cable (AWG26 wire)
23 oz., 660 g
Technical data