8.3
Technical data - mechanical design
Size (lange)
Flange
Protection DIN EN 60529
Operating speed
Range of switching speed
Operating torque typ�
Rotor moment of inertia
Admitted shaft load
Materials
Operating temperature
Relative humidity
Resistance
Corrosion protection
Weight approx�
Connection
HMG10-B - PROFINET
Shaft type
HMG10-T - PROFINET
Shaft type
MB248EN - 11171699, 16A3, Baumer_HMG10-PROFINET_II_EN
ø105 mm
Support plate, 360° freely positionable
IP 66/IP 67
≤6000 rpm
±2���6000 rpm,
default 6000 rpm
10 Ncm
2
950 gcm
≤450 N axial
≤650 N radial
Housing: aluminium alloy
Shaft: stainless steel
-40���+85 °C
95 % non-condensing
IEC 60068-2-6
Vibration 30 g, 10-2000 Hz
IEC 60068-2-27
Shock 400 g, 1 ms
IEC 60068-2-52 Salt mist
Complies to ISO 12944-5:1998
Protective paint systems (C5-M)
2�2 kg (depending on version)
Bus connecting box
Terminal box speed switch/incremental
ø16���20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
ø16���20 mm (through hollow shaft)
TECHNICAL DATA
26/29