ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
)
5.2.6
Assignment connecting terminal
Do not connect voltage supply to outputs! Danger of damage!
Please, beware of possible voltage drop in long cable leads (inputs and out-
puts)!
5.2.6.1
Connecting terminal box [B]
Speed switch without additonal output
SP+*
dnu
dnu
dnu
dnu
dnu
dnu
5.2.6.2
Connecting terminal box [B]
Speed switch with additonal output
SP+*
+UB
* Only at version with speed switch
MB254EN - 11173973, 16A1, Baumer_HMG10-EtherCAT_II_EN
A+
A _
B+
B _
SP-*
dnu
dnu
dnu
dnu
SA*
SB*
SP-*
nE+
nE _
R+
R _
SA*
SB*