Baumer Hubner Berlin PMG10 Manual de instrucciones - Página 30

Navegue en línea o descargue pdf Manual de instrucciones para Media Converter Baumer Hubner Berlin PMG10. Baumer Hubner Berlin PMG10 44 páginas. Absolute encoder
También para Baumer Hubner Berlin PMG10: Instrucciones de montaje y funcionamiento (32 páginas), Instrucciones de montaje y funcionamiento (32 páginas)

Baumer Hubner Berlin PMG10 Manual de instrucciones
6
|
Electrical installation
6.9.3

Assignment second flange connector

NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
Additional incremental output 2 (optional)
Speed switch (optional)
The TTL/HTL output (Vin = Vout) at the additional incremental output 2 is galvanically isolated
and requires separate voltage supply.
7
6
Ill. 14: Flange socket M23 (male, 12-pin, clockwise)
PIN
1
2
3
4
5
6
I
Additional output incremental (optional)
II
Speed switch (optional)
30
8
1
9
10
12
2
3
11
4
5
Assignment
dnu / B−
I
nE− 
dnu / R+
dnu / R−
dnu / A+
dnu / A−
Operating Manual
PIN
I
7
8
I
9
I
10
I
11
I
12
Baumer Hübner
Assignment
II
dnu / SP+
I
dnu / B+
II
dnu / SP−
I
0V
I
nE+ 
I
Ub 3)
PMG10 & PMG10P SSI | V1