Baumer Hubner Berlin POG 9+ESL Instrucciones de montaje y funcionamiento - Página 7
Navegue en línea o descargue pdf Instrucciones de montaje y funcionamiento para Media Converter Baumer Hubner Berlin POG 9+ESL. Baumer Hubner Berlin POG 9+ESL 32 páginas. Incremental encoder with integrated electronic speed switch
2
Security indications
2.1
Risk of injury due to rotating shafts
Hair and clothes may become tangled in rotating shafts.
• Before all work switch off all voltage supplies and ensure machinery is stationary.
2.2
Risk of destruction due to electrostatic charge
Electronic parts contained in the device are sensitive to high voltages.
• Do not touch plug contacts or electronic components.
• Protect output terminals against external voltages.
• Do not exceed maximum voltage supply.
2.3
Risk of destruction due to mechanical overload
Rigid mounting may give rise to constraining forces.
• Never restrict the freedom of movement of the device.
The mounting instructions must be followed.
• It is essential that the specified clearances and/or angles are observed.
2.4
Risk of destruction due to mechanical shock
Violent shocks, e. g. due to hammer impacts, can lead to the destruction of the sensing system.
• Never use force.
Mounting is simple when correct procedure is followed.
• Use suitable puller for dismounting.
2.5
Risk of destruction due to contamination
Dirt penetrating inside the device can cause short circuits and damage the sensing system.
• Absolute cleanliness must be maintained when carrying out any work on the device.
• Never allow lubricants to penetrate the device.
2.6
Risk of destruction due to adhesive fluids
Adhesive fluids can damage the sensing system and the ball bearings. Dismounting a device,
secured to a shaft by adhesive may lead to the destruction of the device.
2.7
Explosion risk
Do not use the device in areas with explosive and/or highly infammable materials. They may
explode and/or catch fre by possible spark formation.
MB068.2 - 11114905
Baumer_POG9-ESL_DE_EN_202209_MI_11114905 (22A1)
Security indications
2
4