Baumer Hubner FOG 9 + GT 7 Manual de instrucciones de instalación y funcionamiento - Página 28
Navegue en línea o descargue pdf Manual de instrucciones de instalación y funcionamiento para Media Converter Baumer Hubner FOG 9 + GT 7. Baumer Hubner FOG 9 + GT 7 32 páginas. Combination incremental encoder + tachogenerator
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
Interference immunity:
•
Emitted interference:
•
Approval:
•
9.2
Technical data - electrical ratings (tachogenerator)
Reversal tolerance:
•
Linearity tolerance:
•
Temperature coefficient:
•
Isolation class:
•
Calibration tolerance:
•
Climatic test:
•
Armature-circuit time-constant:
•
FOG 9 + GT 7.08
Performance:
•
Open-circuit voltage:
•
FOG 9 + GT 7.16
Performance:
•
Open-circuit voltage:
•
9.3
Technical data - electrical ratings (encoder)
Voltage supply:
•
Consumption w/o load:
•
Pulses per revolution:
•
Phase shift:
•
Duty cycle:
•
Reference signal:
•
Output frequency:
•
Output signals:
•
Output stages:
•
9.4
Technical data - mechanical design
Size (flange):
•
Shaft type:
•
Shaft loading:
•
Flange:
•
Protection DIN EN 60529:
•
Operating speed:
•
Operating torque typ.:
•
Rotor moment of inertia:
•
25
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE
≤0.1 %
≤0.15 %
±0.05 %/K (open-circuit)
B
±5 %
Humid heat, constant
(IEC 60068-2-3, Ca)
<4 μs
0.3 W (speed ≥5000 rpm)
10...30 mV per rpm
0.6 W (speed ≥5000 rpm)
40...60 mV per rpm
9...30 VDC (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
100...5000 (As ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
≤120 kHz; ≤300 kHz option
K1, K2, K0 + inverted
Error output (only EMS)
HTL-P (power linedriver)
TTL/RS422
(As ordered)
ø115 mm
ø11 mm solid shaft
≤200 N axial; ≤300 N radial
EURO flange B10
IP55
≤10000 rpm
6 Ncm
160 gcm²
Baumer_FOG9-GT7_II_DE-EN (16A2)
MB195.1 - 11098542