ELECTRICAL CONNECTION / ELECTRICAL CONNECTION WITH RADIAL TERMINAL BOXES
5.7.2
Assignment connecting terminal
)
Do not connect voltage supply to outputs! Danger of damage!
Please, beware of possible voltage drop in long cable leads (inputs and out-
puts)!
5.7.2.1
Connecting terminal first terminal box [A]
SSI
Programming interface (only PMG10P)
Additional output incremental 1 (option)
dnu / SA
dnu / SB
dnu / A+
dnu / A−
dnu / B+
dnu / B−
5.7.2.2
Connecting terminal second terminal box [B]
Additional output incremental 2 (option)
Speed switch (option)
)
dnu / SP+
dnu / A+
dnu / A−
dnu / B+
dnu / B−
Additional output incremental (option)
1)
Speed switch (option)
2)
Programming interface (only PMG10P)
3)
19/29
3)
3)
1)
1)
1)
1)
Ub
0V
The TTL/HTL output at the additional output incremental 2 is electrically
isolated and requires a separate power supply�
2)
1)
1)
1)
1)
Ub
1)
0V
1)
nE+
nE−
PRE
DIR
D+
D−
C+
C−
dnu / SP−
nE+
nE−
dnu / R+
dnu / R−
dnu
dnu
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN