Baumer CleverLevel LBFH Manual de instrucciones - Página 12

Navegue en línea o descargue pdf Manual de instrucciones para Instrumentos de medida Baumer CleverLevel LBFH. Baumer CleverLevel LBFH 48 páginas. Point level detection – hygienic/industrial level measurement

Baumer CleverLevel LBFH Manual de instrucciones
CleverLevel
Point level detection – hygienic/industrial
9.

Troubleshooting

Fault
LED does not light up
Red LED indicator light
LED flashes red

10. Cleaning, maintenance and repair

Cleaning
Clean, disinfect or sterilize sensor as needed
f
„
(CIP/SIP).
Maintenance
Regular maintenance is not required.

11. Disposal

Do not dispose of in household
f
„
waste.
Separate materials and dispose
f
„
of in compliance with nationally
applicable regulations.

12. Accessories

For adapter and other accessories see www.baumer.com.

13. Technical data

Environmental conditions
Operating temperature
range
Storage temperature range
Ambient humidity
Protection class
Oscillations (sinusoidal)
(EN 60068-2-6)
12 / 48
Level measurement
LBFH/I
®
Cause
Sensor not correctly connected
Short circuit
Unsuitable media characteristics
Device error
-40 ... -85 °C
„„
-40 ... -85 °C
„„
< 98 % RH,
„„
condensing
IP67
„„
IP69K (with
„„
appropriate cable)
1.6 mm p-p
„„
(2 ... 25 Hz),
4 g (25 ...100 Hz),
1 octave / min.
Operating Instructions
Action
Check plug and power supply.
f
„
Remedy short circuit.
f
„
Check signal quality with
f
„
FlexProgrammer.
Dismount and return sensor.
f
„
Repair
Do not repair the sensor yourself.
Send damaged sensor to Baumer.
f
„
Features
Repeatability
„„
Hysteresis
„„
Response time
„„
Damping
„„
± 1 mm
± 1 mm
0.04 s
0.1 ... 10.0 s (adjustable)
www.baumer.com