8 Heartbeat Service

8.1

General

The device supports a heartbeat producer according CiA 301.
8.2

COB-ID

The COB-ID for the heartbeat message is 700h + node ID.
8.3

Timing

The minimal cycle time for heartbeat messages is 1 ms.

9 LSS slave

9.1

General

The baud rate and node ID can be configured by LSS (according to CiA 305). Another possibility to change the baud rate
and node ID is to access to the objects 0x3000 and 0x3001 (see object directory).
The LSS service is only available in NMT Stopped Mode.
9.2

Supported commands

Switch state global
Switch state selective
Configure node ID protocol
Configure bit timing parameters
Store configuration
Inquire identity serial number
Inquire identity node ID
9.3

LSS address

The needed value for LSS addressing as serial number is printed on a label on the encoder housing.
Baumer_GCA5_CANopen_MA_EN_V1_02.docx
28.09.2016
13/16
Baumer Electric AG
Frauenfeld, Switzerland