Functions
INFO
When several sensors are calculated, for example, for thickness measurement, the Standard fil-
ter should always be chosen to obtain a raw measured value of both sensors for further calcula-
tions.
IO-Link parameter: Filter operating mode
Parameter name
Operation Mode.Precision
Filter
MovAvgFilter.Custom Mov-
ing Average Length
MovMedianFilter.Custom
Moving Median Length
24
Values
Standard, High,
Very High, High-
est, Custom
-
-
Operating Manual
Description
Selection among predefined filters
n
(number of measured values per filter).
Custom: Enter the filter length as a nu-
n
merical value.
Freely configurable filter length for Mov-
n
ing Average.
Freely configurable filter length for Mov-
n
ing Median.
Baumer