10.3

Type data

Open-
voltage
Type
[mV/rpm]
TDP0,2LT(LS)-6
TDP0,2LT(LS)-7
TDP0,2LT(LS)-10
TDP0,2LT(LS)-5
TDP0,2LT(LS)-4
TDP0,2LT(LS)-3
TDP0,2LT(LS)-1
TDPZ0,2LT-7
TDPZ0,2LT-10
TDPZ0,2LT-5
TDPZ0,2LT-4
TDPZ0,2LT-3
Superimposed ripple (for τ
10.4

Replacement switching diagram

Polarity for positive direction of rotation, see section 5:
TDP:
TDP:
1A1/2A1: +
R
L
A
A
U
(n)
0
Tachogenerator
τ
τ
≈ R · C
RC
MB079a - 11068397
Minimum load required
circuit
depending on speed range
(DC)
0 - 3000:
U
R
0
L
[kΩ]
10
≥0.1
20
≥0.3
30
≥0.7
40
≥1.2
60
≥2.7
100
≥7.5
150
≥16
Twin tachogenerator with two separate tachogenerator voltages
(The data refer to each of the two tachogenerator outputs)
20
≥1.2
30
≥2.7
40
≥4.8
60
≥11
100
≥30
= 0.7 ms): ≤0.5% peak-peak
RC
A1: +
A2: -
1A2/2A2: -
R
A1
U(n)
R
L
A2
L
A
R
A
L
Baumer_TDP02-TDPZ02-B3_II_DE-EN (20A1)
[rpm]
0 - 6000:
0 - n
max
R
R
L
L
[kΩ]
[kΩ]
≥0.3
≥0.9
≥1.2
≥3.3
≥2.7
≥7.5
≥5
≥13.5
≥11
≥30
≥30
≥30
---
≥30
≥4.8
≥14
≥11
≥30
≥20
≥54
≥44
≥120
≥120
---
≤0.2% rms
(VDE)
(VDE)
C
U(n) = U
(n)
0
Maximum
Armature
operating
resistance
speed
:
n
R
(20°C)
max
A
[rpm]
[Ω]
10000
10000
10000
10000
10000
6000
271
4000
630
10000
10000
10000
10000
160
6000
445
U(n)
-n
-U(n)
R
L
≈ U
(n) for R > R
R
+ R
0
A
L
10
Armature
inductance
L
A
[mH]
3
6
11
23
26
50
47
90
99
200
550
1260
19
45
42
103
70
170
390
1080
U
(n) ≈ U(n)
0
n
>> R
L
A
24