Baumer SXC40c Manual del usuario - Página 17

Navegue en línea o descargue pdf Manual del usuario para Cámara digital Baumer SXC40c. Baumer SXC40c 48 páginas. Sxc series cameralink cameras with truesense imaging sensors
También para Baumer SXC40c: Manual de inicio rápido (2 páginas)

Baumer SXC40c Manual del usuario
6.2.2.4. Non-overlapped Operation
If the frequency of the trigger signal is selected for long enough, so that the image acquisi-
tions (t
+ t
) run successively, the camera operates non-overlapped.
exposure
readout
Trigger
Exposure
Readout
TriggerReady
Flash
t
min
t
triggerdelay
t
exposure(n)
t
readout(n)
t
notready
t
flash(n)
t
flashdelay
t
exposure(n+1)
t
readout(n+1)
t
flash(n+1)
Timings:
A - exposure time
frame (n) effective
B - image parameters
frame (n) effective
C - exposure time
frame (n+1) effective
D - image parameters
frame (n+1) effective
E - earliest possible trigger
Image parameters:
Offset
Gain
Mode
Partial Scan
17