Step 8:
Crimp plug contact assembly (Part 3).
Cable Size
16 mm
2
25 mm
2
Notes: The recommended crimp sizes are only for reference. The customer should adjust them according to cable
specification and crimp tool and test results including temperature rise and metallographic analysis and pullout force.
Recommended crimping tool: Manual hydraulic crimping
Die: 25mm
die for 25mm
2
Die: 16mm
die for 16mm
2
Step 9:
Install heat shrink tubing to the area where crimping contact and wire.
Amphenol P/N: CH53X-005-09A ( Part 4)
Notes: Don't let the shrink tubing cover the braid wire
Tooling: Heat gun as shown in picture
Recommended heat shrink tubing spec: Without hot melt adhesive
Excellent sealing and insulation properties
Shrink ratio: 2:1
Operating temperature: -55~125°C
Recommended crimp
length of Side S
6.0
6.0
cable
2
cable
2
Recommended crimp length is 10
0.5mm Gap
Recommended crimp
dist across Flats F
7.0±0.1mm
7.5±0.1mm
±
0.5mm
Recommended Min. Cable
Pullout Force (N)
1500
1900