8 Installation
8.1 Electrical connection
Make the electrical connections as specified in Sections 11.2 Electrical data, 11.3 Pin assignment, and 11.6
Wiring instructions.
Mounting
8.2
(1) Scatec-10: Mount the sensor at a
mounting height h of 70 +/-2mm above
or below the conveying plane with the
front windows parallel (+/-3°) to the
conveying plane.
Scatec-15: Mount the sensor at a
mounting height h of 100 +/-2mm above
or below the conveying plane with the
front windows parallel (+/-3°) to the
conveying plane.
(2) Adjust the sensor so that the laser
beam is aimed towards the edges to be
counted. Note that the laser beam is
focused into a line which must be
aligned in parallel to the edges to be
detected!
(3) Block the laser beam after the objects
whenever possible.
(4) Keep the window clean (no fingerprints).
(5) A direct line of sight from the laser
impact point to the entire front window
must be ensured.
Comments:
Mounting height: h
Tilting tolerance
Overlap orientation
Front windows
User manual Scatec-10 / -15
Version 2017-10
Scatec-10:
70 +/-2mm above or below the conveyor belt
The resolution depends on the working distance. The highest resolution of 0.10 mm
edge thickness is achieved at a working distance d of 68 – 72 mm. (See also section
11.8 Application data)
Scatec-15:
100 +/-2mm above or below the conveyor belt
The resolution depends on the working distance. The highest resolution of 0.15 mm
edge thickness is achieved at a working distance d of 97 – 103 mm. (See also
section 11.8 Application data)
max. +/- 3°
The edges to be counted must face toward the laser beam (front edges) whether
they are leading or trailing.
Make sure, that the laser line is parallel to the edge to
be detected!
The direct line of sight from the impact point of the
laser to the entire front window must not be obstructed
by any hardware for potential laser impact points in a
distance range d of 0 – 150 mm (for Scatec-10) or 0 –
200 mm (for Scatec-15) If mounting brackets or other
components are close, consult a technician from
Baumer Electric.
www.baumer.com
Scatec-1x
Scatec-15:
4
h=100 mm
1
Scatec-10:
h= 70 mm
Clean windows
Laser line focus
transverse to the Scatec
10 / 44
+/- 3°
1
5
2
Beam blocker
3
Scatec-1x
d
Scatec-15: d=200 mm
Scatec-10: d=150 mm
Baumer Electric AG
Frauenfeld, Switzerland