Baumer NE216 Manual de instrucciones - Página 8
Navegue en línea o descargue pdf Manual de instrucciones para Caja Baumer NE216. Baumer NE216 22 páginas. Electronic preset counter
NE216
Sensor
Contact
Proximity switch PNP or NPN
Namur without explosion protection
Incremental encoder
30
3.5 Examples of connection
Contact assignment Programming
3.6 Connecting the sensor supply
Connect the sensor supply at terminals 12 and 13 – for example en-
coder supply, etc.
Do not use the sensor supply to supply non-earthed inductive or
capacitive loads. The sensor supply is short-circuit proof (exception
model 24/48 VAC).
Voltage supply
24 VAC
48 VAC
85...265 VAC
12...30 VDC
www.baumer.com
7
Track A
12
+24 V
7
Track A
12
+24 V
13
0 V
7
Track A
13
0 V
7
Track A
8
Track B
12
+24 V
13
0 V
Sensor supply
10...26 VDC
10...26 VDC
24 VDC ±20 %
9...28 VDC ±20 %
Counting rate:
Line 31 to 1 = 25 Hz
Line 31 to 2 = 3 Hz
Input logic:
Line 33 to 0 = PNP
Line 33 to 1 = NPN
Input logic:
Line 33 to 1 = NPN
Counting mode:
A 90° B (x1, x2, x4)
Line 30 to 3, 4, 5
Counting rate:
Line 31, 32 to 0 = 10 kHz
Current load
60 mA
60 mA
100 mA
100 mA