Baumer N 150 Manual de instrucciones - Página 16
Navegue en línea o descargue pdf Manual de instrucciones para Equipamiento industrial Baumer N 150. Baumer N 150 21 páginas.
N 150
Extended identifier command „AX" (41h,58h)
This extended command is utilized to address individual SPAs in the bus network in a similar way as described
above. By broadcast command the identifier to be assigned is transmitted to all networked SPAs as follows:
SOH
Adr
Cmd
Cmd2 Identifier = 01
EOT
CRC
Transmission
01h
83h
41h
58h
30h
31h
04h
40h
Similar to the standard command all N 150 now indicate the identifier just transmitted and that is to be assigned
in the upper display line. Adopting the identifier is the same way. However, contrary to the above there won't be
any acknowledging „B" replied. Checking whether the new identifier has been adopted is up to master,, for
example utilizing command "R" (read actual value). The R-command is transmitted with the corresponding
identifier to the N 150. If the addressed SPA is confirming that the assignment was successful, the master can
proceed with next identifier. Regarding other commands the display of the respective SPA switches to standard
operation.
www.baumer.com
16