Follett HCE1000ABS Manual de instrucciones de instalación - Página 5

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Fabricador de hielo Follett HCE1000ABS. Follett HCE1000ABS 16 páginas. For ice storage bins. ice machine models with ride technology

Follett HCE1000ABS Manual de instrucciones de instalación
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• H_C1000(A/W)BS 208-230/60/1-15 amps
• H_E1000(A/W)BS 230/50/1-15 amps
(H_E1000A/W requires 15A circuit, 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water fi ltration system (#00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
• The drain line from the ice machine must have at least 1/4" per foot pitch (6,4mm/0,3m)
BIN • RIDE Technology
H_E1000A/W
requires 15A circuit,
H_C1000A/W
2
1.50 mm
wire
H_E1400A/W
requires 20A circuit,
2
4.00 mm
wire
H_C1400A/W
2
wire)
self-contained
NEMA
6-15
NEMA
6-20
• H_C1400(A/W)BS 208-230/60/1-20 amps
• H_E1400(A/W)BS 230/50/1-20 amps
(H_E1400A/W requires 20A circuit, 4.00 mm

Site preparation

1/4" (6,4mm)
1' (0,3m)
2
wire)
2
5