INSTALLATION INSTRUCTIONS

CONFORMITY TO REGULATIONS AND LAWS
The appliance is to be installed by an authorised person in
accordance with AS5601 - the installer must ensure the
installation complies with all regulatory and manufacturer
requirements and operationally and functionally test, make
necessary adjustments and commission the appliance as part
of installation.
WARNING
The manufacture declines any responsibility if these
obligations are not respected.
INSTALLATION
The overall dimensions, position/dimensions of connections
and technical data are given in the installation diagram.
If the appliance cannot be adjusted to perform correctly call
the tecnichal assistant service.
Positioning
• Install the appliance in a suitably ventilated environment.
• Position the appliance at least 15 cm from surrounding
walls. This distance may be reduced if the walls are
flameproof or protected by insulating material.
• This appliance is not designed for built-in installation.
• Remove the protective film from the external panels.
Use a suitable solvent to remove any glue residue.
• In stand-alone installations, appliances 40 or 60 cm wide
must be fixed to the floor using the flanged feet.
• Level the appliance by means of the adjustable feet.
• In case of installation on a level bench top, it must be used
the approriate feets equipped with the applince (height = 30
mm).
Joining appliances together in line ( Fig. 1 )
• Remove the control panels ( Fig. 1A ).
• Remove the fixing screw nearest the control panels, from
each side to be joined ( Fig. 1B ).
• Place the appliances next to each other and level them until
the tops match ( Fig. 1C ).
• Insert the coupling plate ( supplied ) into the side housings
on the backs. Join together the appliances screwing M5
flathead screws ( supplied ) in to coupling plate ( Fig. 1D ).
• Turn 180º one of the two plates inside the appliances to be
joined together ( Fig. 1E ).
• Join together the appliances , at the front side, screwing the
M5x40 screw ( supplied ) on the opposite insert (Fig. 1F ).
Connecting to the gas supply
• Install a shut-off valve upstream of the appliance, in a
place easily accessible.
• Check if the appliance is adjusted for the type of gas with
which it will be supplied. If not, convert it according to the
instructions in the paragraph "Conversion to different type of
gas".
• Do not use supply pipe having a diameter smaller than the
appliance's gas connection.
• Check that there are no leaks at the connection points.
Connecting to the electrical power supply
• The appliance is set to operate at the voltage indicated on
the data plate.Total power is given in table T6 in Technical
Data section.
• The appliance must be supplied with a separate electrical
line using a flexible rubber cable with insulating properties
not inferior to H07RN-F. The length of the cable between the
cable clamp and the connection terminal blocks must be such
that the live conductors tighten before the yellow/green earth
wire, in case the cable come out of the cable clamp.
(CR0687760) 9
• Install suitable automatic cut-off switches (contact opening
of at least 3 mm) and highly sensitive automatic differential
protection devices. These must guarantee protection against
direct or indirect contact with live parts and against currents
towards earth in the event of malfunction (maximum
dispersion current 1 mA/kW).
• To access terminal board remove the front panel.
• Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied whit the appliance.
Earth and equipotential connection
• The appliance must be earth connected on the terminal
block marked by the symbol
terminal block.
• The metal structure of all the appliances installed must be
connected together on the terminal marked by the symbol
located close to the earth terminal (equipotential system).
CONVERSION TO A DIFFERENT TYPE OF GAS
To convert the appliance to a different gas supply, follow the
instructions below.
Use the injectors contained in the bag supplied with the
appliance.
Replacement of burner injector and pilot burner injector
of cooking hob (Fig. 2A / 2B )
• Remove pan grids, burner units, front panel.
• Unscrew the existing injectors "U" / "UP" and replace them
with the ones indicated in Table T1 in Technical Data
section.
Replacement of burner injector and adjustment of
burner air flow of solid top (Fig. 2E)
• Remove front panel.
• Unscrew the existing injector "U" and replace it with the
one indicated in Table T1 in Technical Data section.
• Position the air regulator at the distance "A" indicated in
Table T2 in Technical Data section.
• Retighten screw V and seal it with red paint.
Replacement of pilot burner injector of solid top(Fig. 2F)
• Remove plate , front panel.
• Unscrew fitting R and replace injector "UP" with the one
indicated in Table T1 in Technical Data section.
• Retighten fitting R.
Adjustment of minimum flow to the cooking hob burners
and solid top burner (Fig. 3A)
• Remove the front panel.
• Unscrew the existing screw "VM" and replace it with the
one indicated in Table T1 in Technical Data section.
Replacement of burner injector and adjustment of
burner air flow of oven (Fig. 2C)
• Remove the panel under oven's door.
• Unscrew screw "V".
• Unscrew the existing injector "U" and replace with the one
indicated in Table T1 in Technical Data section.
• Position the air regulator at the distance "A" indicated in
Table T2 in Technical Data section.
• Retighten screw V and seal it with red paint.
Replacement of pilot burner injector of oven (Fig. 2D)
• Remove the panel under the oven's door.
located beside the input line