ADA collar details and installation requirements
If dispenser is to be installed in a 34" (864mm) high counter for ADA compliance, a
!
.9" (23mm) stainless steel "collar" must be installed between dispenser and counter
to provide necessary clearance. Standard 36" (915mm) counters do not require this
accessory piece. If you need this collar and it was not included with dispenser,
please call Follett to obtain it.
All U300/UD300 dispensers must be installed level in both directions to ensure
!
proper operation and must be supported from below with supplied 6" (153mm) legs,
or with channels installed at site. Do not hang dispenser on flange. These
dispensers weigh approximately 325 lbs (147kg). Use care when maneuvering unit
into position.
All units
1. Make counter cut-out in accordance with instructions on page 8.
2. If not using legs, block up area below counter cut-out to support dispenser.
Procedure for dispensers that will be dropped into a four-sided cut-out:
3. Center collar over counter cut-out opening.
4. If dispenser is equipped with an icemaker, disconnect ice transport tube from its bracket in storage area of
dispenser (if tube enters opposite from tower).
Note: Since this tube must be reinstalled in bracket after dispenser is dropped into counter, note how tube is
held by bracket tabs before disconnecting.
5. Carefully lower dispenser into counter cut-out as described on page 8, adjusting height of dispenser from
below until dispenser flange rests flush on collar and is supported by legs or blocks.
Procedure for dispensers that will be slid into a three-sided cut-out:
3. Slide collar over bottom of dispenser and hold against dispenser counter flange.
4. Carefully slide dispenser into position, keeping ice transport tube clear of counter supports.
5. Adjust height of dispenser from below until dispenser flange rests flush on collar and is supported by legs or
blocks.
All units
6. Apply a bead approximately 1/4" (6mm) in diameter of NSF-listed silicone sealant (Dow Corning RTV-732 or
equivalent) around perimeter of dispenser where it meets collar and smooth sealant to a 1/8" (4mm) radius.
7. Proceed with electrical, plumbing (and ice tube connections on automatic load units) as described beginning
on page 8.